7084 677-00MKvOperating instructions Page 14RefrigeratorRead the operating instructions before switching on for the rst timeGB
22DefrostingThe appliance defrosts automatically. The water that forms on the rear wall drains into a reservoir at the back of the appliance and evapo
23Cleaning and disinfectionAlways switch o the appliance before cleaning and dis-infecting it. Disconnect the appliance from the mains.• Only disinf
24Terminating resistorWhen connecting several appliances via the RS485 interface, the terminat-ing resistor must remain on the last appliance.Remove t
25GB1. Unscrew the hinge bracket.Important: The door mounting has a spring mechanism enabling the door to close by itself. The hinge bracket t
14Type plateAdjustable-height feetOperating and control elementsGrid shelvesThe grid shelves can be moved to accommo-date dierent height bottles or p
15GBSafety instructions and warnings• To prevent injury or damage to the unit, the ap-pliance should be unpacked and set up by two people.• In the eve
16Appliance dimensionsSetting up• Avoid positioning the appliance in direct sunlight or near cookers, radiators and similar sources of heat.• The fl
17GBSymbols in the display Compressor is running LED ashing - refrigeration unit switches on after a delay. The compressor will start automatically
18Door open alarmWhen the door is opened, the LED lights up and the tempera-ture display begin to ash.When the door has been left open for more tha
19GBAlarm testThis test checks the function of the internal and any external connected alarm device.The appliance does not stop its refrigerating func
20Example of an alarm querySituation: HACCP ashes in the display. Display = Display = There has not been an alarm status with a too high or too
21GBSetting the real time clockThe real time clock is preset (CET). Other time zones or summer/winter time must be adjusted manually.Press for 5 seco